The Horiba PA-1100 Environmental Radiation Monitor Radi is ideal to simply measure a fair amount of radiation which exists around the regular living area. Equipped with Bluethooth and USB communication, Horiba PA-1100 is capable of transferring measurement data to PCs, smart phones, or other devices.
Count of 1000 or more per minute when Cs-137 is 1µSv/h
Relative indication error
Within ±10% (error relative to the reference value of Cs-137)
Variation in indicating value
Vriation coefficient less than 0.1
Mesurement energy range
150keV to 1.25MeV or higher
Energy Characteristics
0.5~3 (response ratio at 150 keV to MeV when Cs-37 is 1)
Sampling time
60 seconds
Power supply
1.5V 2 AA batteries (manganese or alkaline batteries)
Display update interval
10 seconds (display every 10 second of moving average in 60 seconds)
Dimensions
68(W) x 28(D) x 121(L) mm Approx. 2.68(W) x 1.10(D) x 4.76(L) in.
Weight
175g(batteries and strap not included) Approx. 6.17 oz.
Bluetooth communications
Dose equivalen rate (µSv/h) data is output via Bluetooth communications. Bluetooth version 2.1+EDR and Serial Port Profile are supported.
USB communications
Dose equivlent rate (µSv/h) data is output via the supplied USB cable. ?Operating environment of communications terminal? ? Supported operating systems
Count of 1000 or more per minute when Cs-137 is 1µSv/h
Relative indication error
Within ±10% (error relative to the reference value of Cs-137)
Variation in indicating value
Vriation coefficient less than 0.1
Mesurement energy range
150keV to 1.25MeV or higher
Energy Characteristics
0.5~3 (response ratio at 150 keV to MeV when Cs-37 is 1)
Sampling time
60 seconds
Power supply
1.5V 2 AA batteries (manganese or alkaline batteries)
Display update interval
10 seconds (display every 10 second of moving average in 60 seconds)
Dimensions
68(W) x 28(D) x 121(L) mm Approx. 2.68(W) x 1.10(D) x 4.76(L) in.
Weight
175g(batteries and strap not included) Approx. 6.17 oz.
Bluetooth communications
Dose equivalen rate (µSv/h) data is output via Bluetooth communications. Bluetooth version 2.1+EDR and Serial Port Profile are supported.
USB communications
Dose equivlent rate (µSv/h) data is output via the supplied USB cable. ?Operating environment of communications terminal? ? Supported operating systems
Product Features
Measures Gamma Ray Radiation
Communication tools facilitate daily data management
?Bluetooth?The GPS data (dima and location) of the portable device and the radiation amount that PA-1100 acquires can be recorded.
?USB? Continuous monitoring of doses is available by collecting data transfered from USB into a PC.
Expanded measurement ranges 0.001-19.99Sv/h
Data imported by connection between PA-1100 and Android devicedisplays insorted colors in a map ? Valid only PC with internet connection