The Tramex IQCK Flooring Installation Quick Check Kit is a compact kit for instant, non-destructive, quantitative moisture content testing of concrete floors and ambient dew-point conditions at the time of installation. Even if pre-installation tests have been performed, checking the %MC and ambient dew-point conditions at the time of installation is crucial to ensure successful installation. The Tramex CME5 Concrete Moisture Encounter Non Destructive Moisture Meter allows for non-destructive quantitative testing of concrete moisture content using Gravimetric testing as a baseline. The Tramex IRT2DP Infrared Surface Thermometer And Dew Point Detector provides surface temperature readings and ambient temperature and dew point conditions to avoid condensation-related issues at the time of installation and floor failures.